Chest Clip 3ms
Overview
Chest clip 3ms is used in the CTI calculation.
Inputs
Signals:
- Resultant Chest Acceleration (G's)
Calculation
Calculation from SAE 1727 [1],
- Filter chest accelerations (CFC = 180)
- Linear interpolate to a time step that is a multiple of the time window
-- Single peal and cumulative peak 2. Calculate the longest sustained acceleration over 3ms
![]() | ![]() |
---|---|
Injury Criteria
Limits for Chest Acceleration and Chest Deflection [2],
ATD | Chest Acceleration Limit |
---|---|
HIII - M95 | 55 |
HIII - M50 | 60 |
HIII - F05 | 60 |
HIII - 6yo | 60 |
HIII - 3yo | 55 |
CRABI - 12mo | 50 |
References
[1] "Calculation Guideline for Impact Testing" No. J1727-2015-02 SAE International. SAE Technical Report, 2015.
[2] Eppinger, Rolf, et al. "Development of improved injury criteria for the assessment of advanced automotive restraint systems." (1998).
[3] Eppinger, Rolf, et al. "Supplement: development of improved injury criteria for the assessment of advanced automotive restraint systems: Ii." (2000).